beautypg.com

Maintenance procedure preparation, Recommendations, Equipment needed – Water Inc WI-BG-PURE User Manual

Page 15: Activating the system, Do not use the first storage tank of water

background image

9

ACTIVATING THE SYSTEM

CAUTION: Make sure all water supply lines, drain lines and fittings are secure and free from leakage.


1

. Open source water supply valve. Close product water

faucet. Check for leakage.


2. Turn tank valve one-quarter turn counter-clockwise to

open valve (handle should be in line with tubing as it
enters connection).


3. Confirm system is producing water. Module will be

sending rinse water to drain.


4. Remove manifold cover if attached by gently lifting

cover up and away from manifold.

CAUTION:

Wiring within module cover connects

monitor components. If wires, circuit board, or

connections are damaged and/or wetted, monitor will

not function.


5.

CAUTION:

Verify battery connector alignment

before making connection (Page 11, Figure 9).

Connect battery on manifold by pressing clip onto
battery terminals.


6. Replace manifold cover by gently pushing cover onto

manifold until it snaps into place.


7. Test battery connection by activating monitor. Press

push button. If either indicator light illuminates,
connection is good.

NOTE:

Release button after light illuminates. Test is to

confirm battery connection, not water quality.




8. Open product water faucet and let water flow until all air

has been expelled from system.

9. Close product water faucet. In 30 minutes, check

connections for leaks and correct if necessary.

Icemaker/Extra point of use: Check connections on
these supply lines for leaks.


10. Allow storage tank to fill overnight.

11. WARNING: DO NOT USE THE FIRST FULL

STORAGE TANK OF WATER

Discard (to drain) first full tank of water by opening
product water (and extra point-of-use) faucet until water
flow stops, then close faucet. This will flush sanitizing
solution from system.

Icemaker: Let tray/bin fill with ice cubes. Discard all
ice cubes. This flushes sanitizing solution from lines to
icemaker.


12. System is ready to use. Should there be any aftertaste

or odor to water or ice cubes, repeat Steps 10 and 11.










DO NOT USE THE FIRST STORAGE TANK OF WATER

Allow storage tank to fill overnight. Dispense this water to drain.

This process removes factory-installed sanitizing solution from the entire system and sends it to drain.

This process also sanitizes fittings and tubing used during installation.

MAINTENANCE PROCEDURE PREPARATION

RECOMMENDATIONS

HAVE ALL EQUIPMENT AND REPLACEMENT COMPONENTS ON HAND AND READY BEFORE BEGINNING PROCEDURE.

A CLEAN WORK AREA AND EQUIPMENT ARE ESSENTIAL TO PROPERLY CLEAN AND/OR SANITIZE THE SYSTEM.

(i.e., CLEAN HANDS, TOOLS, WORK SURFACE, AND CONTAINERS)

EQUIPMENT NEEDED

Safety glasses

Rubber gloves, sanitary

Wash Cloth, Clean and Lint-free

Liquid dish soap

Household bleach - Unscented Only

(5.25% sodium hypochlorite)

Plastic storage bag

Manual Air Pump

Plastic bucket

Plastic bowl

“O” ring Lube FDA Approved