beautypg.com

Item, Drain outlet assembly installation – Water Inc WI-BG-PURE User Manual

Page 10

background image

4

DRAIN OUTLET ASSEMBLY INSTALLATION

NOTE: State, provincial and local plumbing codes may prohibit use of saddle-tapping drain connections and may

require use of an air gap.

NOTE: Location and orientation of drain outlet assembly is vital to system performance.

Horizontal Drain Line:

Locate drain hole as close as possible to top of pipe

(between 45º and top) and as far as practical from

garbage disposal.

Vertical Drain Line:

Locate drain hole on a straight length of drainpipe next to

"P"/"S" trap between trap and sink.


Figure 4: Drain Hole Location and Installation, Air Gap Faucet

NOTE: See Page III, Figure 1.A. for connection to drain for Non-Air Gap Faucet.


1. Select a location for drain hole based on type of sink

and orientation of drain line (Figure 4).



2. Position drain outlet saddle (Figure 5, Item 1) on

drainpipe. Allow adequate space for drilling operation.


3. Tighten saddle bolts evenly on both sides. Avoid over-

tightening.


4. Using opening in drain saddle outlet as a guide, drill a

3/8" to 7/16" diameter hole in drainpipe. Clean any
debris out of drain saddle connection.

Item

Description

Part No.

1

Drain Saddle, Air Gap, 3/8” Connection

92160

Figure 5: Drain Outlet Assembly