Gas Requirements

Shut off main gas supply valve before disconnecting the old
range and leave it off until the new hook-up has been
completed. Don’t forget to relight the pilot on other gas
appliances when you turn the gas back on.

Electrical Requirements

Refer to data plate for more information. See the product
“Data Plate” in the section on Service in this manual.

Gas Models

The 120v power cord is installed on gas ranges.

Dual Fuel Models

We recommend that the range be installed with a
power cord set (not supplied). The electrical rating
of the power cord set must be 120/240 volt, 30 amperes
minimum. The power cord set shall be marked “For Use
with Ranges.” Always use a new power cord.

Note: In Canada, the range is shipped from the factory with
the range power cord already installed.

Electrical kW Rating

Ranges are dual rated for use on either 120/240 VAC or
120/208 VAC. Check the data plate for the kW rating.
Reference the kW rating in the table below to determine
amperage requirements.

* Varies by location. Check local codes.

Electric Outlet and Gas Connection
Location

Dual Fuel models: A flush mount 208/240 VAC outlet is
recommended. Use the diagram below to make sure your
installation in properly prepared for the range. Note the
grey box (E) designating the acceptable area on the wall
behind the range for the 208/240 VAC electrical outlet.

Gas Models: The power cord and outlet are 120 VAC. The
120 VAC outlet can be positioned on the wall and outside
the gas connection area and below 20 in. (51 cm) from the
floor.

Dual Fuel and Gas Models: The gas connection is
accessed by removing the warming drawer. The available
space for the gas connection is shown in the grey box (G)
in the illustration following.

Verify that wiring to house is adequate Contact your local
utility company to verify that the present electric service to
your home is adequate. In some instances, the size of the
wiring to the house andservice switch must be increased to
handle the electrical load demanded by the range.

Verify that wiring inside house is adequate. Most wiring
codes require a separate circuit with separate disconnect
switch and fuses either in the main entrance panel or in a
separate switch and fuse box

The range requires a minimum of a three wire 120/240 or
120/208 volt, 40 or 50 AMP, 60 Hz AC circuit. Check local
codes for proper amperage ratings.A four wire connection
is preferred. Most local building regulations and codes
require that electrical wiring be done by licensed
electricians. Be sure to install your range according to the
electric codes in place in your region.

9 WARNING

Make certain that gas shutoff valve and all burner
controls are in the OFF position before beginning.

VOLTS

A/C

HZ

RATING

KW

CIRCUIT

BREAKER

120/240

60

13.0

40 or 50 amps*

120/240

60

13.8

40 or 50 amps*

120/208

60

9.8

40 or 50 amps*

120/208

60

10.4

40 or 50 amps*