Aci_eject2, Aci_eject2 -42, Figure 4-34 – ADIC Server User Manual
Page 84: Figure 4-35, Table 4-16, Para

4-42
DAS ACI Functions
601626-B
aci_eject2
The aci_eject2 function ejects a range of volumes from the
AML. See Figure 4-34.
Figure 4-34
aci_eject2 Function Call
For the structure of the aci_ei_info function, refer to
Figure 4-35.
Figure 4-35
Structure of the aci_ei_info function from aci.h
See Table 4-16 for a description of the parameters for the
aci_eject2 function call.
Table 4-16
Parameters for the aci_eject2 Function Call
Parameter
Description
eject_area
logical area defined in the AMS, where the cartridges should be
ejected
volser_range
• a single volser
• multiple volsers separated by commas
• a range of volsers separated by a hyphen
• set to empty (““ or ‘\0’) if it is not to be changed
type
media type of the named volser range
Refer to Media Types on page 2-7
pnActualCount
returned number of ejected volsers
#include "aci.h"
int aci_eject2( char *eject_area,
char *volser_range,
enum aci_media type,
int *pnActualCount,
struct aci_ei_info *psteiInfo)
struct aci_ei_info {
char volser[ACI_VOLSER_LEN];
char media_type[ACI_DRIVE_LEN];
int errcode
};