beautypg.com

Table 4-36, Para, Attention – ADIC Server User Manual

Page 136

background image

4-94

DAS ACI Functions

601626-B

The aci_partial_inventory function is intended for testing
and startup. An error function will be displayed in the AMU
log during operation (and not returned to the calling
process). The database segments that are defined in the
function cell will be overwritten with a symbolic volser
“*Ixxxx” if the barcode reader malfunctions.

Table 4-36

Parameters for the aci_partial_inventory Function Call

Parameter

Description

SourCoor

10 digit logical coordinate of the device for the start of the
inventory (defined in the AMU database), e.g. L501010101

TargetCoor

10 digit logical coordinate of the device for the end of the
inventory (defined in the AMU database), e.g. L501011310
Source and targeted must be in the same device.

Attention