beautypg.com

Figure 4-69, Table 4-29, Para – ADIC Server User Manual

Page 120

background image

4-78

DAS ACI Functions

601626-B

Volsers which already have a entry in the AMU database,
will be moved to this position.

Volsers which have no entry in the AMU database, will be
moved to the first free slot (AMU database Attribute:
"Empty" of this media type of the Type AMU-Dynamic)

With insertopt -c will move the cartridges to the first
free slot (AMU database Attribute: "Empty") of this media
type of the Type AMU-Dynamic. The attribute will
automatic change to Clean

Cartridges with an invalid volser (barcode not readable)
will be moved to the problembox.

The function returned the inserted volser with the following
structure. See Figure 4-69.

For additional information, refer to aci_eject on page 4-39.

Figure 4-69

aci_ei_info Structure from aci.h

See Table 4-29 for a description of the parameters for the
aci_insert2 function call.

Table 4-29

Parameters for the aci_insert2 Function Call

Parameter

Description

insertopt

defined the type of media for the insert operation

-n

normal (data cartridges)

-c

clean (cleaning cartridges)

areaname

Logical insert range of the Insert/Eject unit of the AML
in the AMS (e.g. I03)

cleanPoolname

Name of the Cleanpool defined in AML (must be NULL,
if insertopt= n)

pnActualCount

Number of inserted volsers and pointer to an array of
structure

struct aci_ei_info {

char

volser[ACI_VOLSER_LEN];

char

media_type[ACI_DRIVE_LEN;

int errcode

}