ADIC Server User Manual
Page 208

A-8
Application Notes
601626-B
35
ESWITCHINPROG
The commands can not be executed. DAS and
AMS are being switched to the other AMU. Wait
until the switching process is completed and try
again.
36
ENOPOOL
There has been an attempt to insert or eject
cleaning cartridges to a cleanpool that has not
been configured. Confirm the cleanpool name in
the command with the cleanpool names in the
AMS configuration.
37
EAREAFULL
The aci_ejectclean command returns that the Eject
area is full. Empty the area and try the command
again.
38
EHICAPINUSE
The commands can not be executed, because the
HICAP is open and the robot is not ready. Close
the HICAP, press the start button on the
controller and try the command again.
39
ENODOUBLESIDE
The volser in the aci_getvolsertoside command
was not from type optical disk (AMU mediatype
O0 and O1)
Check the AMS configuration and AMU
database.
40
EEXUP
The aci_driveacess command returned that the
requested drive is exclusively used by a other
client. Request the other client to release the drive
or use the Client DAS_SUPERVISOR for the
release.
41
EPROBDEV
AMS returned <1033> (position not in AMU
database). Check the AMU database, use AMS
command update device for actualizing the
database.
42
ECOORDINATE
AMS returned <1142> (the logical coordinate is
not in the AMS configuration). Compare the AMS
configuration with the DAS parameter in the
command.
43
EAREAEMPTY
Returned AMS <1156> (Insert area empty) during
insert. Open and close the I/O unit, the AMS will
start the automatic inventory of the range.
44
EBARCODE
Switch the bracode reading off with aci_barcode
and try the command again
Table A-1
Error Code Reactions
Number
d_error Name
Recommended Reactions to the Error Code