2 afe option setup – Atmel ATAK2270 User Manual
Page 31
Host Software
5-18
RFID Application Kit ATAK2270 User Manual
4871E–RFID–04/08
Not released in Basic Mode:
Terminator:
– Basic Mode
Sequence Terminator
– Extended Mode
Sequence Start Marker Terminator
Initial. Delay:
Modulation switch on delay after POR (0 = 192 Tc; 1 = 8192 Tc)
Inverse Data:
Data uplink is performed inversely when activated (default = not activated)
Fast Downlink:
Reduces clock cycles for logical 1/0 detection (default = not activated)
OTP:
Allows a general data protection (default = not activated)
Note:
If the selected settings are not supported by the reader, a warning message is displayed before the config-
uration is executed.
5.3.6.3.2 AFE Option Setup:
In the Analog Front-End (AFE) Option section, the behavior of the transponder can be influenced in
terms of damping and modulating during downlink and uplink operation. Selected parameters are sent to
the transponder by clicking the Write AFE-Option Set Button. Default parameters that are needed for
Basic Mode are indicated in bold.
Clamp Voltage:
Clamp Low, Clamp Medium, Clamp High
Soft Modulation
No Soft Modulation, One Pulse Weak, One Pulse Strong, Two
Pulses, Smooth
Gap Detection Threshold
Low, Medium, High
Clock Detection Threshold
Low, Medium, High
Modulation Voltage
Modulation Low, Modulation Medium, Modulation High
Modulation Delay
No Delay, One Pulse Delay, Two Pulses Delay
Write Damping
WD and Low Attenuation, WD and High Attenuation, Low
Attenuation, High Attenuation, WD Only, OFF
Downlink Protocol
Fixed Bit Length, Long Leading Ref, Leading Zero Ref, 1of 4
Coding Ref
Lock Block 0:
Setting this bit locks the whole configuration block of the
transponder. Once locked, the configuration can never be
changed. Use this feature with care.
Note:
Changing the setup of Write Damping or Downlink Protocol has an impact on the write timing. For later
reconfiguration, if the write timing is not known, configuration will not be possible.