Brother HL-1240 User Manual
Page 48
2-6
Table 1: Serial Interface Parameters Settings
Selector
Parameters
On (up)
Off (down)
1
Baud Rate
See Table 2
2
Baud Rate
See Table 2
3
Data Length
7 bits
8 bits
4
Stop Bit
2 bits
1 bit
5
Parity
See Table 3.
6
Parity
See Table 3.
7
Protocol
Xon/Xoff + DTR
DTR only
8
Robust Xon
On
Off
Table 2: Baud Rate Settings
Selector 1
Selector 2
For RS-422A
For RS-232C
Off
Off
57600
9600
On
Off
9600
4800
Off
On
1200
1200
On
On
19200
19200
Table 3: Parity Settings
Selector 5
Selector 6
Parity
On
On
Odd
On
Off
Even
Off
Off
None
✒ Note
•
The factory settings are indicated in bold ( all switches OFF ).
•
If the robust Xon setting is turned on with selector 8, the printer sends Xon
signals at one second intervals to the connected computer until it receives data. It
is effective only if selector 7 is set to the On position for the Xon/Xoff plus DTR
setting.