Emc) – UEi Test Instruments C127OILKIT User Manual

Page 5

background image

b

atterieS

r

ePlaCemeNt

This meter has been designed for use with both alkaline

and rechargeable Nickel Metal Hydride (NiMH) batteries.

No other types are recommended. The analyzer is supplied

with 4 “AA” size alkaline batteries.

These should be installed into the instrument as shown

in the diagram to the right and indicated on the back of

the unit.

CAUTION!

Take great care when installing the batteries to observe

correct polarity. Always check the meter for operation

immediately after installing new batteries.

u

SiNg

r

e

-C

hargeable

b

atterieS

The battery charger must only be used when NiMH batteries are fitted. Alkaline batteries are not

re-chargeable. Attempting to recharge alkaline batteries may result in damage to the product and may

create a fire risk.

b

attery

C

hargiNg

Ensure that you use the correct charger. This unit uses a 9V DC regulated charger.

Ensure that the batteries are fitted in the correct manner, and then charge for at least 16 hours. Subsequent

charges should be overnight. NiMH batteries may be charged at any time, even for short periods to

conduct testing.

WARNING!

Under NO circumstance should you expose batteries to extreme heat or fire as they may explode and cause

injury. Always dispose of old batteries promptly in a manner consistent with local disposal regulations.

e

leCtromagNetiC

C

omPatibility

(emC)

This product has been tested for compliance with the following generic standards:

EN 50081-1, EN 50082-1 and is certified to be compliant.

The European Council Directive 89/336/EEC requires that electronic equipment does not generate

electromagnetic disturbances that exceed defined levels and has an adequate level of immunity to enable it to

be operated as intended.

Since there are many electrical products in use that pre-date this Directive and may emit electromagnetic

radiation in excess of the standards defined in the Directive there may be occasions where it would be

appropriate to check the analyzer prior to use. The following procedure should be adopted.

• Go through the normal start up sequence in the location where the equipment is to be used

• Switch on all localized electrical equipment that might be capable of causing interference

• Check that all readings are as expected (a level of disturbance in the readings is acceptable)

• If not, adjust the position of the instrument to minimize interference or switch off, if possible, the

offending equipment for the duration of the test

At the time of writing this manual (July 2006) UEi is not aware of any field based situation where such

interference has ever occurred and this advice is only given to satisfy the requirements of the Directive.

Note: Follow battery

directions on back of

housing

Battery Compartment

Cover

Back of

Instrument

4

5

C75 Directions

C125/C127 Directions

OR