beautypg.com

Eagle s, Pecifications – UEi Test Instruments C127OILKIT User Manual

Page 19

background image

EAGLE S

PECIFICATIONS

18

19

Features

C75

C125

C127

Worklight

4

4

Low battery indicator

4

4

Individual print-out reports

4

4

Rotary selector

4

4

4

Memory positions (various tests)

20

179

179

Infrared printer port

4

4

4

Backlit display

2 Lines

4 Lines

4 Lines

Boot with integral magnet

4

4

4

User programmable headers

4

4

4

Time & date stamp

4

4

4

Temp Measurement

Flue Temp Range (T1 C125/C127)

32 ~ 1112˚F / 0 ~ 600˚C

20 ~ 2400˚F / -29 ~ 1315˚C

Inlet Temp Range:Probe (T2 C125/C127)

-

Inlet Temp Range: Ambient

32 ~ 112˚F / 0 ~ 50˚C

32 ~ 112˚F / 0 ~ 50˚C

Net Temp (∆T)**

32 ~ 1112˚F / 0 ~ 600˚C

20 ~ 2400˚F / -29 ~ 1315˚C

Resolution

1˚F/˚C

0.1˚F/˚C

Flue (T1, Inlet T2, & Net ∆T) Accuracy

±[0.3% rdg +5˚F(3˚C)]

±[0.3% rdg +3.6˚F(2˚C)]

Inlet Temp Ambient Accuracy

±[0.3% rdg +1˚F(1˚C)]

±[0.3% rdg +1.8˚F(1˚C)]

Gas Measurement

Oxygen

0 ~ 21%

0 ~ 21%

0 ~ 21%

O2 Resolution/Accuracy

0.1% / ±0.2%*

0.1% / ±0.2%*

0.1% / ±0.2%*

Carbon Monoxide

0 ~ 1000 ppm

0 ~ 4000 ppm

0 ~ 4000 ppm

CO Resolution/Accuracy

1 ppm/±10 ppm < 100 ppm*

1 ppm/±10 ppm < 100 ppm*

1 ppm/±10 ppm < 100 ppm*

±5% reading

±5% reading

±5% reading

Carbon Dioxide**

0 ~ 30%

0 ~ 30%

0 ~ 30%

CO2 Resolution/Accuracy

1.0%/±0.3% reading

1.0%/±0.3% reading

1.0%/±0.3% reading

Efficiency**

0 ~ 99.9%

0 ~ 99.9%

0 ~ 99.9%

Efficiency Resolution/Accuracy

0.1%/±1.0% reading

0.1%/±1.0% reading

0.1%/±1.0% reading

Excess Air**

0 ~ 250%

0 ~ 250%

0 ~ 250%

Excess Air Resolution/Accuracy

0.1%/±0.2% reading

0.1%/±0.2% reading

0.1%/±0.2% reading

CO/CO2**

-

0 ~ 0.999%

0 ~ 0.999%

CO/CO2 Resolution/Accuracy

-

0.0001%/±5% reading

0.0001%/±5% reading

Nitric Oxide

-

-

1 ppm/±2 ppm < 30 ppm*

Nitric Oxide Resolution/Accuracy

-

-

±5 ppm > 30 ppm

Pressure (Differential)

Range ±0.2mBar 0.08”wg

0.001mBar/±0.005mBar ±0.002”wg

0.001mBar/±0.005mBar ±0.002”wg

Range ±1mBar 0.4”wg

0.001mBar/±0.03mBar ±0.01”wg

0.001mBar/±0.03mBar ±0.01”wg

Range ±80mBar 32”wg

0.01mBar/±3% reading

0.01mBar/±3% reading

Pre-Programmed Fuels

Natural Gas, Propane, Butane, LPG, Light Oil

Eagle Dimensions

Weight

2.2lbs. with boot

Handset

7.9 x 1.8 x 3.5”

Probe

11.8 x 0.25 x 9.4” stainless steel shaft, type K thermocouple (9’ hose)

Operating temp

0 to 40˚C/10% to 90% Relative Humidity non-condensing

Battery

x4 “AA” cells / 12 hour life typical with Alkaline “AA” cells

Warranty

3 year limited warranty (2 year sensor warranty)

*Measures **Calculates