6 setting a communications speed, 7 setting an address – TOHO ELECTRONICS TRM-006A User Manual
Page 6

6
2.2 Setting a data length
2.3 Setting a stop bit length
2.4 Setting a parity
2.5 Setting whether to conduct a BCC check
While in the "Set a communications parameter" screen on the preceding page, operate the ▲ and
▼ keys to make the settings. The initial value is
H H H H
.
^ g f o
****
F
Stop bit 1
I
Stop bit 2
c
No parity
f
Odd parity
D
Even parity
N
Data length, 7 bits
E
Data length, 8 bits
c
BCC check disabled
j
BCC check enabled
2.6 Setting a communications speed
While in the "Set a communications speed" screen on the preceding page, operate the ▲ and ▼
keys to make the settings. The initial value is
H H.
^ j T L
****
I
1200 BPS
K
2400 BPS
E
4800 BPS
M
9600 BPS
F
I
19200 BPS
2.7 Setting an address
While in the "Set a communications address" screen on the preceding page, operate the ▲ and ▼
keys to make the settings. The initial value is
H
.
^ i d h
F
Setting range: 1 to 99 stations (It cannot be set to a 0.)