6

2.2 Setting a data length

2.3 Setting a stop bit length

2.4 Setting a parity

2.5 Setting whether to conduct a BCC check

While in the "Set a communications parameter" screen on the preceding page, operate the ▲ and
▼ keys to make the settings. The initial value is

H H H H

.

^ g f o

****

F

Stop bit 1

I

Stop bit 2

c

No parity

f

Odd parity

D

Even parity

N

Data length, 7 bits

E

Data length, 8 bits

c

BCC check disabled

j

BCC check enabled


2.6 Setting a communications speed

While in the "Set a communications speed" screen on the preceding page, operate the ▲ and ▼
keys to make the settings. The initial value is

H H.

^ j T L

****

I

1200 BPS

K

2400 BPS

E

4800 BPS

M

9600 BPS

F

I

19200 BPS


2.7 Setting an address

While in the "Set a communications address" screen on the preceding page, operate the ▲ and ▼
keys to make the settings. The initial value is

H

.

^ i d h

F

Setting range: 1 to 99 stations (It cannot be set to a 0.)