Specifications
Electrical Specifications
Parameter voltage and current levels
Testing for the currents listed in
assume a static test setup with measurements performed while
static data is applied to the device. Test type parameters apply as listed in the
Table 4: Inputs
Test Type
Vil
a
Vih
a
Iil
b
Iih
b
AIB (analog input)
0.2 Vdd
2.0 Vdd
0.0 to -1.0 µA
0.0 to 1.0 µA
IBA (CMOS)
0.25 Vdd
0.8 Vdd
0.0 to -1.0 µA
0.0 to 1.0 µA
IBT (CMOS, SC
Hsy = 1.0)
c
0.2 Vdd
0.8 Vdd
0.0 to -1.0 µA
0.0 to 1.0 µA
a.
CMOS values are V
IN
x V
DD
.
b.
Iil and Iih are tested at V
DD
= 3.6 V. Not tested at less than room temperature.
c.
SC = Schmitt
Table 5: Outputs
Test Type
Vol Voh Iol
a
Ioh
a
OB 1
b
<0.4 V
>2.4 V
1.0 mA minimum
-1.0 mA minimum
OB 2
b
<0.4 V
>2.4 V
1.0 mA minimum
-1.0 mA minimum
OB 3
c
0.267 V
1.936 V
10 mA minimum
10 mA minimum
a. Polarity on currents indicate direction of current ( + ) for sinking ( - ) for sourcing.
b. V
DD
= 4.5 to 5.0 V
c.
V
DD
= 2.2 V
Table 6: I/O Pins
Test
Type
Vil
a
Vih
a
Vol
b
Voh
b
Iol
b
Ioh
b
Ioz
c
Ioz
c
IO1A
CMOS
<.30 V
>.70V
<0.40 V
4.1 V
-0.64 mA
-0.15 mA
39µA
minimum
217 µA
maximum
a. CMOS values are V
IN
x V
DD
.
b. Tested at V
DD
= 4.8 V
c.
Tested with V
DD
= 5.2 V. Leakage on I/O pins is typically checked for ± 2 µA with the ouput device turned off and no
PU or PD.
PNI Corporation 133 Aviation Blvd., Suite 101, Santa Rosa, CA 95403‐1084 USA;, Fax: (707) 566‐2261
For the most current specifications, please visit our website at:
www.pnicorp.com
‐ 3 ‐