Ps0, ps1, and ps2 – period select, Ratio, Odir – oscillator direction – PNI ASIC User Manual
Page 12: Mot – magnetic oscillator test, Aso & asi – axis select, Function, 2 mhz scaling, X axis, Y axis, Z axis
![background image](/manuals/373153/12/background.png)
PNI ASIC
Host Processor Interface
PS0, PS1, and PS2 – Period Select
Selects the division ratio applied to the L/R oscillator output to set the period being measured
.
Table 11: Period Select
PS2
PS1
PS0
Ratio
0
0
0
/32
0
0
1
/64
0
1
0
/128
0
1
1
/256
1
0
0
/512
1
0
1
/1024
1
1
0
/2048
1
1
1
/4096
ODIR – Oscillator Direction
Determines the magnetic oscillator direction if MOT is set to 1. It has no effect on direction when the MOT
bit is set to zero. This is used for debug purposes only, and will not be set in normal operation.
MOT – Magnetic Oscillator Test
When set, causes the magnetic oscillator selected by AS0 and AS1, in the directions selected by ODIR to
run continuously until PNI ASIC is reset.
ASO & ASI – Axis Select
Determines which axis is being measured.
NOTE
When 2 MHz scaling is selected, the magnetic sensor oscillator does not run. Instead, the internal
2 MHz oscillator is turned on. The 2 MHz clock cycles are counted until a command byte is sent
disabling the scaling function. A RESET stops the 2 MHz oscillator and clears all bits.
Table 12: ASO and ASI Axis Select
Function
AS1
AS0
2 MHz scaling
0
0
X axis
0
1
Y axis
1
0
Z axis
1
1
PNI Corporation 133 Aviation Blvd., Suite 101, Santa Rosa, CA 95403‐1084 USA;, Fax: (707) 566‐2261
For the most current specifications, please visit our website at:
www.pnicorp.com
‐ 12 ‐