6. Wiring
When wiring to external contacts for the signal line, use non-voltage contacts such as a relay, switch or an NPN
(PNP type also available� open collector circuit. Refer to table 1 below for contact capacity.
Refer to table 3 “Contact Capacity” on the following page.
• Wiring Example
• BSV-24N (NPN Transistor Type�
Power (+) White
Power (-) Black
CH1 Sky Blue
CH2 Yellow
CH3 Peach
CH4 Light Green
Fuse
Fuse
Power (+)
Power (-)
CH1
CH2
CH3
CH4
(COM)
(COM)
Do not short Power (+) to the CH lines. Failure do to so will result in damage to the product.
NPN Transistor Circuit
Non-voltage Contact Circuit
* The power (-) shares the same common as the signal ground.
• Double check the wiring to prevent mistakes. Failure to conform may result in product damage, resulting
in damage to the circuitry or fire.
WARNING
• Be sure the power is disconnected before wiring or installing this product. Possibility of electric shock,
short-circuiting or product failure may occur.
• Do not pull or tug at the wires with excessive force. Failure to comply will result in damage to the product.
CAUTION