beautypg.com

Ouellet OWC-R User Manual

Page 23

background image

23

Q.9: Is it mandatory to have a ground fault circuit-breaker-detector?
R.9:
Although Canadian regulations in effect do not require the installation of a ground fault circuit-breaker/
detector, we highly recommend its use for concrete cable applications. In the United States, a ground fault
circuit interrupter (GFCI) must be used with this heating device in bathrooms and in hydromassage bathtub
locations as long as any others concrete cable installations.

Q.10: Must we have a temperature sensor?
A.10:
Yes. This will control the floor surface temperature so it does not exceed the maximum temperature
allowable for the type of floor covering used. Although it is not mandatory to have a temperature sensor when
the system is used with an ambient air thermostat, Ouellet Canada Inc. recommends using a temperature
sensor as well.

Q.11: Can two OWC-R concrete cable systems be connected to the same thermostat?
A.11:
Yes, (more if need be) parallel-connected if the total capacity does not exceed that of the thermostat.

Q.12: What happens when the voltage applied is the wrong one?
A.12:
A product intended for 240/208V connected to 347V: there will be overheating and then a breakdown will
occur. It is therefore very important to connect the product to the proper voltage.