• Never attempt to cut or shorten a heating cable.

• Be very careful while maneuvering around the heating cables.

• It is important not to subject heating cables to any kind

of mechanical stress (stretching, bend radius less than

1.5” (38 mm), notches).

4.5.2 Installation of temperature sensor

1. Once the cables are unrolled, install the cable duct for the temperature sensor at the pre-determined

location.

Note: The ideal location for the temperature sensor is a site exempt from any obstacles (walls,
doors, etc.).

2. Feed the temperature sensor into the appropriate cable duct and locate it between two parallel

OWC-R cable.

3. The temperature sensor must be installed as near as possible to the floor surface and solidly anchored

with a piece of wood or polystyrene foam so it will not shift during the concrete pouring process;

Note: Make sure the sensor is long enough to be connected to the thermostat.

The temperature sensor must be

completely encased in concrete.

WARNING!

WARNING!