beautypg.com

2 always, 3 never – Ouellet OTR User Manual

Page 6

background image

6

1.2 Always

– Read this guide in full before installing the product;

– Install the Therma Cable system with a regulating device;

– Use copper wires only;

– Perform the mandatory tests described in this guide and record readings on the

table of measures;

– Only use cement or an equivalent binder compatible with floor heating systems

(cement glue, ceramic glue, self-levelling cement);

– Ensure that the black heating cable is completely embedded in cement or an equiv-

alent binder (cement glue, ceramic glue, self-levelling cement);

– Ensure that the voltage supplied equals the nominal voltage of the Therma Cable

system;

– Repair the product only using the Therma Cable repair kit available at your autho-

rized Ouellet Canada Inc. dealer;

– Consult Ouellet Canada Inc.’s team of technical specialists for any questions or for

more information;

– Install Therma Cable at temperatures over 5 °C (40 °F).

– Heating cables must be at least 13 mm (½”) away from any combustible surface.

– Metal structures or materials used for the support of or on which cables or sets are

installed be grounded in accordance with the Canadian Electrical Code (CSA C22.1
Section 10 and National Electrical Code).

– The installer of series heating cable sets must inspect and remove damaged or

defective heating cable sets before they are covered or concealed;

– Installer of series heating cable sets must mark the appropriate circuit breaker

reference (label) indicating which branch circuit supplies the circuit to those electric
heating cables.

1.3 Never

– Install Therma Cable sections so that the heating cables are less than 76 mm (3”)

from each other. The temperature could be too high and could cause damages;

– Shorten or alter any part of the heating cable (Fig. 1.3);

– Cross, overlap, or stack heating cables (they must not touch);

– Connect a 120V product to a 240V/208V power source;

– Use a bending radius under 20 mm (¾”);

– Install a temperature regulator (thermostat or other) where it is accessible from the

shower or bath (install at least 1 m [3’ 4”] away);

– Staple heating cable or floor sensor end to the subfloor (Fig. 1.3);

– Install the Therma Cable system if the safety seal is broken;

– Install the Therma Cable system under a closet or fixed items.

– Series heating cable sets shall not extend from beyond the room or area in which

they originate;

– Series heating cable sets are not to be installed in walls.

– Exceed the 15 Amp limit per thermostat or power unit if you intend to add a OTR

product to one of them. Please refer to the related OTR table products to deter-
mined if the amperage limit was reached or not, by adding a OTR product to the
thermostat or power unit (or relay). If the amperage limit is over 15 Amp then you
will need to add a power unit for the additional product needed in this room.