beautypg.com

Technical data, Information – NORD Drivesystems B1091-1 User Manual

Page 18

background image

Motors in fi operation for Category 3D – Planning guideline for B 1091

18

B 1091-1 GB-3213

2. Technical Data

Data:

Motor type:

IE1 and IE2 *

Category:

3D

Mains voltage:

400 V

Circuit: See

tables

Surface temperature:

T125 °C / T140 °C

Ambient temperature Tu:

max. 40 °C

* Values also apply for IE2 (Labelling xH), e.g. 80LH/4

Pos: 35 /Anleitungen/Motoren/B1091-1 Projektierungsleitfaden zur B1091/2. Technische Daten/2.1 Motoren/2.1 Motoren [B1091-1] @ 2\mod_1358759456932_388.docx @ 53819 @ 2 @ 1

2.1 Motors

Information

Increased ambient temperature

Operation is possible up to an ambient temperature of 60 °C. The stated torques must then be reduced to 72 %.

Information

Interpolation

A linear interpolation of the data between adjacent frequencies is permissible.

Pos: 36 /---------- Seitenumbruch ---------- @ 1\mod_1329145698658_0.docx @ 15891 @ @ 1