FUTEK IPM52x (D520) Digital Display User Manual
Page 8
Revision 00
\\Sql\Sales\Rachel\TECH SALES INFO\FUTEK PRODUCTS\Digital Displays\D520\Instructions\RS232 CONNECTIONS.doc
Page 8 of 9
Table 22: 20pt Linearization Commands
Table 23: Input Signal Commands
Table 24 and 25: Second Scale Commands and Command Codes
Menu
Point
Number
Command
Code
Point Value
XX
=Value Corresponding to
Point Number
R or D
= R - Input, D-Output
XX
=1-20, Linearization Points
LN
=Linerazation Setup Command
Menu
Channel
Number
Command
Code
Command
Options
X
=1-0-20mA, 2-
0-10V, 3-+/-
30mV, 4-+/-
20mV, 5-
+/-2V, 6-+/-
100mV
T
= Input type
1 or 2
=Channel Number
CH
=Input Setup Command
Menu
Command
Code
Command
Options
X
= Command Option
XX
=Command Code (Table 25)
S2
=Second Scale Command
Command
Code
Command
Function
Command
Options
ON
On/Off Selection
0-Off, 1-
On
DP
Decimal Point
Selection
0- XXXXX
1-XXXX.X
2-XXX.XX
3-XX.XXX
4-X.XXXX
5-.XXXXX
CH
Channel Selection
1-Channel1
2-Channel2
3-Channel3
LO
Low Signal Input Default 0.0
HI
High Signal Input
Default: Rated
Output (mV)
DL
Low Display Value Default: 0.0
DH
High Display Value
Default: Max
Capacity