FUTEK IPM52x (D520) Digital Display User Manual
Page 6
Revision 00
\\Sql\Sales\Rachel\TECH SALES INFO\FUTEK PRODUCTS\Digital Displays\D520\Instructions\RS232 CONNECTIONS.doc
Page 6 of 9
Table 10: Shunt Commands
Table 11 and 12: Peak Commands and Command Codes
Table 13 and 14: Remote Commands and Command Codes
Table 15 and 16: Remote 2 Commands and Command Codes
Menu
#
Command
Code
Command
Option
X
=0-display 20 updates w/
shunt relay on 1-
complete shunt CAL
function
X
= Command Code (Table 12)
1 or 2
=Peak number
FP
= Peak Function
Command
Code
Command
Function
Command
Options
N
On/Off Selection
0-Normal mode
1-Peak mode
H
Hi/Lo Peak
Selection
0-Valley 1-
Peak
C
Channel Selection
1-Channel1
2-Channel2
3-Channel3
G
Gross/Net
Selection
0-Net 1-
Gross
RMT
#
Command
Code
XX
= Command Code (Table14)
1, 2, 3, or 4 =Remote number
RMT
=Remote Setup Command
Command
Code
Command
Function
0
RESET
1
TARE
2
HOLD
3
SCALE 2
4
LOCK
5
PEAK 1
6
PEAK 2
7
ALARM
8
DEC_PT
9
CHANNEL
10
GROSS
11
PEAK_RESET
RT
#
Command
Code
XX
= Command Code (Table16)
1, 2, 3, or 4 =Remote number
RT
=Remote2 Setup Command
Command
Code
Command
Function
Command
Options
D
Remote Decimal
Point Function
0- XXXXX
1-XXXX.X
2-XXX.XX
3-XX.XXX
4-X.XXXX
5-.XXXXX
C
Remote Channel
Function
1-Channel1
2-Channel2
3-Channel3
G
Remote Gross/Net
Function
0-Net 1-
Gross