FUTEK IPM52x (D520) Digital Display User Manual
Page 5
Revision 00
\\Sql\Sales\Rachel\TECH SALES INFO\FUTEK PRODUCTS\Digital Displays\D520\Instructions\RS232 CONNECTIONS.doc
Page 5 of 9
Table 6: Display Commands
Table 7: Update Commands
Table 8 and 9: Function Key Commands and Command Codes
Menu
#
1, 2, or 3
= Channel number
DISP
= Display channel command
Menu
#
1, 2, 3, or 4 = 1-1/Sec, 2-3/Sec, 3-10/Sec, 4-ASAP
UPDT = Display Update Command
Menu
#
Command
Code
XX
= Command Code (Table 9)
1, 2, 3, or 4 =F-key number
FNC
=F1-F4 Key Setup Command
Command
Code
Command
Function
0
ALARM 1
1
ALARM 2
2
ALARM 3
3
ALARM 4
4
TARE 1
5
TARE 2
6
TARE 3
7
CHAN 1
8
CHAN 2
9
CHAN 3
10
ALARM_RESET
11
SCALE 2
12
NET
13
SHUNT
14
PEAK 1
15
PEAK 2
Menu
#
Command
Code (S)
Command
Option
0 or 1
=0-display 20 updates w/
shunt relay on 1-
complete shunt CAL
function
S
= Shunt Command
1, 2, or 3
=Channel number
FN
= Shunt Function