2 measuring, Range, And precision – Dwyer HM35 User Manual
Page 23
22
4.2
Measuring Range and Precision
The measured values display works in the range from -10 % to 110 % of the
measurement range.
Measuring
rage
Unit
Pressure type
Resolution
Max.
Loading
Max.
static pressure
1)
0 ... 10
inH
2
O
d,g
0.0001
50 inH
2
O
245 psi
0 ... 28
inH
2
O
d,g
0.001
140 inH
2
O
245 psi
0 ... 80
inH
2
O
d,g
0.001
600 inH
2
O
245 psi
0 ... 120
inH
2
O
d,g
0.001
600 inH
2
O
245 psi
0 ... 200
inH
2
O
d,g
0.001
1600 inH
2
O
245 psi
0 ... 14.5
psi
d,g
0.0001
58 psi
245 psi
0 ... 15.9
psi
a
0.0001
58 psi
--
0 ... 29
psi
a,d,g
0.001
100 psi
245 psi
0 ... 100
psi
a,d,g
0.001
245 psi
245 psi
0 ... 145
psi
d,g
0.001
390 psi
390 psi
0 ... 245
psi
d,g
0.01
390 psi
390 psi
0 ... 500
psi
g
0.01
1000 psi
--
0 ... 1000
psi
g
0.01
2000 psi
--
0 ... 1300
psi
g
0.01
2000 psi
--
Measuring
range
Unit
Accuracy
Inert
gases
Media compatibility
% FS
% Rdg.
% FS
% Rdg.
2)
2)
0 ... 10
inH
2
O
0.1 / 0.2
--
--
--
0 ... 28
inH
2
O
0.05 / 0.1 / 0.2
0.1
--
--
0 ... 80
inH
2
O
0.1 / 0.2
--
--
--
0 ... 120
inH
2
O
0.05 / 0.1 / 0.2
0.1
--
--
0 ... 200
inH
2
O
0.1 / 0.2
--
--
--
0 ... 14.5
psi
0.05 / 0.1 / 0.2
0.1
0.1 / 0.2
--
0 ... 15.9
psi
0.1 / 0.2
--
--
--
0 ... 29
psi
0.05 / 0.1 / 0.2
0.1
0.1 / 0.2
--
0 ... 100
psi
0.05 / 0.1 / 0.2
0.1
0.1 / 0.2
--
0 ... 145
psi
0.1 / 0.2
--
0.1 / 0.2
--
0 ... 245
psi
0.05 / 0.1 / 0.2
0.1
0.1 / 0.2
--
0 ... 500
psi
--
--
0.1 / 0.2
0.1
0 ... 1000
psi
--
--
0.1 / 0.2
0.1
0 ... 1300
psi
--
--
0.1 / 0.2
0.1
1) a = absolute pressure
d = differential pressure
g = relative pressure
2) 0.1 % Rdg., but not less than 0.03 %FS.