beautypg.com

Crystal T-1-CPF Hydraulic Comparator User Manual

Page 19

background image

Support

17

Type T Pump Operation Manual

X

To Replace the Discharge Check Valve O-ring

1

Remove the plug and O-Ring from the front of the pump body.

2

Replace the O-ring at the base of the plug.

3

Replace the plug.

Replacing the discharge check valve o-ring.

X

To Replace the Vent Valve O-ring

1

Apply a wrench to the nut at the base of the pressure relief valve.

2

Remove the vent valve.

3

Replace the O-ring at the base of the valve.

4

Install the valve.

Replacing the vent valve o-ring.

This manual is related to the following products: