Operation and maintenance, Generating pressure – Crystal T-1-CPF Hydraulic Comparator User Manual
Page 10
Operation and Maintenance
8
Type T Pump Operation Manual
Operation and Maintenance
GENERATING PRESSURE
Note:
It may be necessary to prime the pump, particularly if the pump has been inactive for an extended period of time. Refer to
for instructions on priming the pump.
1
Check that the vent fill plug is fully open by turning it counter-clockwise.
2
Open the vent valve.
Open the vent plug…
then open the vent valve.
3
Set the valve rod selector to control your desired fluid output volume.
!
CAUTION: Only move the valve rod selector while the pump handle is stationary, in the up position.
Note:
With the valve rod in the “out” position, fluid flow will be at maximum and the maximum achievable pressure will be 1000 psi. To exceed 1000 psi, push
the valve rod in.
Low Pressure/
High Volume
High Pressure/
Low Volume