Gage mounting, Figure 5, Table 3 – Badger Meter Ellipse Model PFA User Manual
Page 6: Figure 6, Flow

FLO
W M
ETE
RS
DEB
ITM
ETE
RS
MED
IDO
R D
E F
LUJ
O
F M
APPR
OVED
FLOW
FIELD
WELD
H
L
H
L
Figure 5: Sensor alignment
Pipe Size
Model / Sensor
Weld Connector
Drill Bit
2"…5"
PFA (1/2")
1/8"
3/8"
6"…12"
PFA (7/8")
1/2"
1/2"
14"…16"
PFA (1-1/4")
1"
7/8"
Table 3: Double support drill bit size
Ellipse Sensor
Double Support Pin
Guide Ring
Figure 6: Double support pin
GAGE MOUNTING
1 . The FGE gage can be line, bracket or panel mounted .
2 . For liquid applications, install the FGE below the
PFA Fire Pump System in a level position . See
OTEE:
N
If recommended mounting is not possible, make sure the
gage is vented periodically .
FLOW METERS
DEBITMETERS
MEDIDOR DE FLUJO
F M
APPROVED
F M
APPROVED
PFA-XXX
X inch
250 SWP
X/XX
S/N AXXXXXXX
1000
1500
2000
2500 GPM
3000
3500
4000
VENT
VALVES
FLOW
BYPASS
VALVE
H
L
Figure 7: Recommended installation
Ellipse® Pitot Tube Meter, PFA Fire Pump System
Page 6
April 2014
- BEACON Advanced Metering Analytics (AMA) (2 pages)
- GALAXY (16 pages)
- GALAXY (20 pages)
- GALAXY (28 pages)
- ORION Cellular Endpoint (2 pages)
- ORION Cellular Endpoint (32 pages)
- ORION Cellular Endpoint (80 pages)
- ORION Migratable (ME) (96 pages)
- ORION Migratable (ME) (72 pages)
- ORION Migratable (ME) (60 pages)
- ORION Classic (CE) (2 pages)
- ORION Classic (CE) (20 pages)
- ORION Classic (CE) (2 pages)
- ORION Classic (CE) (28 pages)
- ORION Classic (CE) (8 pages)
- ORION Classic (CE) (16 pages)
- ORION Classic (CE) (32 pages)
- ORION Classic (CE) (20 pages)
- ORION Classic (CE) (28 pages)
- ORION Fixed Network (SE) (4 pages)
- ORION Fixed Network (SE) (48 pages)
- ORION Migratable (ME) (48 pages)
- ORION Migratable (ME) (2 pages)
- ORION Migratable (ME) (32 pages)
- ORION Migratable (ME) (20 pages)
- E-Series Ultrasonic Meters (2 pages)
- E-Series Ultrasonic Meters (12 pages)
- M-Series M2000 (24 pages)
- M-Series M2000 (2 pages)
- M-Series M2000 (4 pages)
- M-Series M2000 (60 pages)
- M-Series M3000 (40 pages)
- M-Series M4000 (36 pages)
- M-Series M5000 (36 pages)
- M-Series M5000 (4 pages)
- M-Series Field Verification Device (24 pages)
- Recordall Disc Series Meters (4 pages)
- Recordall Turbo Series Meters (20 pages)
- Recordall Transmitter Register (RTR) (2 pages)
- Industrial Turbo (16 pages)
- Water Conditioning (16 pages)
- Recordall Compound Series Meters (2 pages)
- Recordall Compound Series Meters (20 pages)
- Recordall Compound Series Meters (16 pages)
- Remote Electronic Display (RED) (8 pages)