Programming Chart for Roots Meters with RIOTronics Pulser
These are typical values but always verify your particular meter configuration and index variables
B3 METER WITH CTR INDEX AND RIOTRONICS PULSER
METER SIZE
INDEX TYPE
DRIVE VALUE
Cu. Ft./Rev.
INDEX RES
Cu. Ft.
# OF INDEX
DIALS
PROGRAMMER
DESCRIPTION
SUBCOUNTS
8C
CTR
5
100
5
5 CuFt REM (100:5) 1
2
11C
CTR
5
100
5
5 CuFt REM (100:5) 1
2
15C
CTR
5
100
5
5 CuFt REM (100:5) 1
2
2M
CTR
5
100
5
5 CuFt REM (100:5) 1
2
3M
CTR
5
100
5
5 CuFt REM (100:5) 1
2
5M
CTR
5
100
5
5 CuFt REM (100:5) 1
2
7M
CTR
5
100
5
5 CuFt REM (100:5) 1
2
11M
CTR
5
100
5
5 CuFt REM (100:5) 1
2
16M
CTR
50
100
6
50 CuFt REM (100:6) 10
1
23M
CTR
50
100
6
50 CuFt REM (100:6) 10
1
38M
CTR
50
100
6
50 CuFt REM (100:6) 10
1
56M
CTR
50
100
6
50 CuFt REM (100:6) 10
1
B3 METER WITH TC (Temperature compensated) INDEX AND RIOTRONICS PULSER
8C
TC
50
100
5
50 CuFt REM (100:5) 10
1
11C
TC
50
100
5
50 CuFt REM (100:5) 10
1
15C
TC
50
100
5
50 CuFt REM (100:5) 10
1
2M
TC
50
100
5
50 CuFt REM (100:5) 10
1
3M
TC
50
100
5
50 CuFt REM (100:5) 10
1
5M
TC
50
100
5
50 CuFt REM (100:5) 10
1
7M
TC
50
100
5
50 CuFt REM (100:5) 10
1
11M
TC
50
100
5
50 CuFt REM (100:5) 10
1
16M
TC
500
100
6
500 CuFt REM (100:6)100
0
Programming Guide
Page 23