Install the orion integral endpoint and – Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual
Page 9
Installation Manual
ORION INTEGRAL ENDPOINT KIT FOR AMERICAN COMMERCIAL DIAPHRAGM
AND TURBINE METER WITH WIRE SEAL SECURITY SCREW
ORION integral
endpoint
4 screws
2 washers
2 large tamper
plugs
2 seal caps
2 small
tamper plugs
Figure 8: ORION integral endpoint kit
OTEE:
N
The screws provided in this installation kit are not drilled for wire seals Therefore, the wire seal is replaced with plastic
seal caps provided in the kit
INSTALL THE ORION INTEGRAL ENDPOINT AND AMERICAN COVER PLATE
Use care when handling the ORION integral endpoint to insure the drive pawl is not subjected to any physical abuse Abuse
may cause this spindle to become bent, misaligned or otherwise inoperative
When attaching an ORION integral endpoint to a gas meter make sure it mounts securely to the meter
1 Place the ORION integral endpoint on top of the gas meter where the index and index cover plate were previously
removed Place the endpoint drive pawl spindle so it is perpendicular to the meter drive pawl
Drive pawl
spindle
Figure 9: Endpoint drive pawl placement
Page 9
July 2014