Adding additional labels, Adding additional labels 7 – Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual
Page 7
Installation Manual
AMERICAN COMMERCIAL DIAPHRAGM AND TURBINE METERS WITH WIRE
SEAL SECURITY SCREW
Index and Index Cover Plate Removal from American Meter with Seal Security Screw
1 Remove the wire security seal from the index cover mounting screw
Figure 1: Wire security seal
2 Use a large screwdriver to remove the four (4) 18-8 index cover mounting plate screws and American index
Discard the four screws
Figure 2: Remove screws on index cover mounting plate
3 Remove the American index and mounting plate
Figure 3: Remove index mounting plate