INDEX REMOVAL FROM SLOPE-FACE METER
1 Use a large screwdriver to puncture and remove the tamper plugs, if present
2 Use a large screwdriver to remove and discard the three (3) cover mounting screws and the cover
Figure 2: Remove cover mounting screws
3 Completely remove and discard the old gasket See
Use a putty knife to clean the meter surface of all gasket
remnants that might limit the effective ness of the new gasket
Figure 3: Completely remove gasket