Place the cover over the endpoint and index, Place the cover over the endpoint and index 12 – Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual
Page 12

ORION® Gas Endpoints, Integral Endpoint for Itron®/Actaris® Residential Slope-Face Gas Meters
2 Screw the endpoint and index onto the gas meter with the three (3) 10-24 X ½" screws (15 in lb maximum)
Figure 16: Screw endpoint and index onto meter
3 Move the odometer or dial TWO-FEET pawls back and forth to verify pawls are connected See
Figure 17: Verify pawls are connected
Place the Cover Over the Endpoint and Index
1 Verify the front lens gasket is properly set around the guide pins See
Figure 18: Verify front lens gasket is properly set
2 Place the cover on the gas meter and tighten it with the four (4) remaining screws (15 inch-pounds maximum) Place the
endpoint IR port on the lower right side of the meter See
Endpoint IR port
Figure 19: Place cover on meter
The endpoint unit is now ready for programming
Page 12
July 2014