16" and 20" meters, Materials, Intentional blank page – Badger Meter Water Conditioning User Manual
Page 19: User manual

16" and 20" Meters
Turbo Series Model
6600
16" (400 mm)
10000
20" (500 mm)
Meter Flanges
Raised-Face Round
Raised-Face Round
Typical Operating Range (100% ± 1.5%)
150…13,200 gpm (34 1…3000 m
3
/h)
300…19,800 gpm (68 1…4500 m
3
/h)
Typical Low Flow (95% minimum)
130 gpm (29 5 m
3
/h)
200 gpm (45 4 m
3
/h)
Maximum Continuous Flow
6600 gpm (1500 m
3
/h)
10,000 gpm (2270 m
3
/h)
Maximum Intermittent Flow
13,200 gpm (3000 m
3
/h)
19,800 gpm (4500 m
3
h)
Pressure Loss at Maximum Continuous Flow
0 5 psi (0 03 bar)
0 5 psi (0 03 bar)
Maximum Operating Pressure
150 psi (10 bar)
150 psi (10 bar)
Maximum Operating Temperature
120° F (49° C)
120° F (49° C)
Materials
Meter Housing
Blue epoxy-coated cast iron
Turbo Head
Cast iron
Nose Cone & Straightening Vanes
Thermoplastic
Rotor
Thermoplastic
Rotor Radial Bearings
Lubricated thermoplastic
Rotor Thruster Bearing
Sapphire jewels
Rotor Bearing Pivots
Passivated 316 stainless steel
Calibration Mechanism
Stainless steel & thermoplastic
Magnet
Ceramic
Register Housing & Cover
Thermoplastic or bronze
Trim
Stainless steel
User Manual
INTENTIONAL BLANK PAGE
Page 19