3.4

ERROR CONDITIONS

If a slave device detects a syntax error or parity error, it will not reply to the

message; the master device should make up to two retries, applying the

two-second No Reply timeout in each case.

Parameter Read operations with parameter identifiers which are in the legal

range but which are not applicable to the addressed instrument will have no

effect on any parameter values and a positive acknowledgement will be

returned.

Parameter Write operations with parameter identifiers which are outside the legal

range will be considered to be syntax errors; no reply will be generated.

Parameter Write operations in which the specified parameter is valid but the

specified value is invalid will generated a negative acknowledgement.