Spectrex Series 300 Open-Path Gas Detection System User Manual
Page 52
Spectrex Inc. - SafEye
TM
300 Gas Detector Manual – TM 794100, Rev. D, May 2004
44
Description
1
Magnetic Mode Selector
5
Horizontal Adjustment Screw
2
Detector Housing
6
Sight Cover Screw
3
Detector Cover
7
Protective Sight Cover
4
Vertical Adjustment Screw
8
Adjustment Screw Securing Nut
Figure 15. Alignment and Mode Selection
Description
1 Telescope Assembly
6
Light Source/Detector Housing
2 Sight Mounting
7
Socket Set Screws (3)
3 Telescope Fastening Screw
8
Vertical Adjustment Screw (2)
4 Periscope
9
Horizontal Adjustment Screw (2)
5 Periscope Fastening Screw
10 Adjustment Screw Securing Nut
Figure 16. SafEye Light Source/ Detector Alignment