Spectrex Series 300 Open-Path Gas Detection System User Manual
Page 30
Spectrex Inc. - SafEye
TM
300 Gas Detector Manual – TM 794100, Rev. D, May 2004
22
4.4 Environmental Specifications
The SafEye system is designed to withstand harsh environmental conditions.
The Source and Detector units compensate for adverse conditions while
maintaining accuracy.
•
High Temperature:
Designed to meet MIL-STD-810C, method 501.1 procedure II
Operating temperature:
+158 ºF (+70 º C)
Storage temperature:
+158 ºF (+70 º C)
•
Low Temperature:
Designed to meet MIL-STD-810C, method 502.1, procedure I
Operating temperature:
-4 º F (-20 º C)
Storage temperature:
-40 º F (-40 º C)
•
Humidity:
Designed to meet MIL-STD-810C, method 507.1, procedure IV
Relative humidity of up to 95% for the operational temperature range.
•
Salt and Fog:
Designed to meet MIL-STD-810C, method 509.1 procedure I.
Exposure to a 5% salt solution for 48 hours.
•
Water and Dust:
IP67 per En60529
IP66 per En60529
Dust:
Totally protected against dust.
Liquids:
Protected against immersion between 15 cm and 1m in depth.
Protected against all water jets from all directions.
•
Shock and Vibration:
Vibration:
Designed to meet MIL -STD-810C, method 514.2,
procedure VIII.
Mechanical Shock:
Designed to meet MIL-STD-810C, method 516.1,
procedure I.
•
Electromagnetic Compatibility (EMC):
The detector is designed and approved according to the following EMC
requirements:
Electrostatic Discharge (ESD)
IEC1000-4-2:1995-1
Conducted emission
EN55011, Class B
Radiated emission
EN55011, Class B
Radiated immunity
ENV50140:1994 (80-1000 MHz)
EFT/B
IEC801-4: 1988