F3 IDLE key: This key will toggle the system between the zone
power levels and the idle power levels. Zone power levels are
displayed in the 6 pie shaped heater sections. The legend in the F3 box
displays IDLE when running or RESUME while in IDLE.
F4 NEXT SCRN key: This key will change the display to the next
screen in the following order: MAIN, RECIPE, ALARMS, and
OPTIONS. Each of these screens has the F4 key active.
F8 PREV SCRN key: This key is active on each of the screens but
has no legend displayed. This key will change the display to the
previous screen in the following order: MAIN, OPTIONS, ALARMS,
and RECIPE.
The system status will display one of the following: OFF, RUNNING,
IDLE, WAITING, and ALARM.
OFF displays when the heater is off and the system is shut down.
RUNNING is displayed when the system is operating at the zone
power settings of the selected recipe.
IDLE is displayed when the system is operating at the idle power
setting of the current recipe.
WAITING displays for one of two conditions: 1. The Remote
Interlock contacts are not closed or jumpered out. 2. The Motion
Detect Option has been enabled and product is not moving. In this
condition the system is ready to go with the zone power levels at 0 and
just “waiting” for the condition to change. Once the condition changes
the power levels go back to the recipe settings
ALARM is displayed when one of the alarm conditions exist. See the
Alarms Screen page for more details.