Technical data – NOSHOK 5301 Series Load Pins User Manual
Page 10

Operating manual
5301 Series Load Pins
10
Technical data
)
3
-
L
I
S
(
1
0
3
5
l
e
d
o
M
Nominal force F
nom
5 / 10 / 20 / 30 / 50 / 100 / 200 kN
5 / 10 / 20 /
30 / 50 kN
Force limit
150 % F
nom
Breaking limit
> 300 % F
nom
Accuracy
< 2 % of F.S. and < 0,5 % of F.S.
< 0,5 % of F.S.
Relative backlash width (Hysteresis)
< 0,5 % of F.S. and <0,2 % of F.S.
< 0,5 % of F.S.
Creeping, 30 min. at F
nom
0,1 % of F.S.
Nominal temperature range
-4 ... 176 °F (-20 … 80 °C)
Storage temperature
-40 ... 212 °F (-40 … 100 °C)
Temperature influence - Meas.range
- Null signal
0,1 % / 10K
0,1 % / 10K
Transverse force action
(signal at 100% nominal load under 90°)
< 5 %
Vibration resistance
20g, 100h, 50...150Hz acc. to DIN EN 60068-2-6
9
2
5
C
E
I
/
9
2
5
0
6
N
E
o
t
.
c
c
a
7
6
P
I
s
s
a
l
c
n
o
it
c
e
t
o
r
P
Interfering emission
acc. to EN 61326
Interference immunity
acc. to 61326
Electrical protection class
Reverse polarity, overvoltage and short circuit protection
Analogue outputs
Output signal
4 … 20 mA – 2-wire or
0 … 10 VDC – 3-wire
4 … 16 mA - 2-L
0 … 7 V - 3-L
Power consumption
Current output: 4 … 20 mA: Signal current
Voltage output:: ca. 8 mA
Auxiliary power
10 ... 30 VDC for output 4...20 mA
14 ... 30 VDC for output 0 ... 10 V
Burden
≤ (UB–10 V)/0,02 A for output 4...20 mA
> 10 kOhm for output 0 ... 10 V
)
.
S
.
F
f
o
%
0
9
o
t
p
u
%
0
1
n
i
h
ti
w
(
s
m
1
≤
e
m
it
g
n
it
s
u
j
d
A
Electrical connection
Round connector M12x1, 4-pin
5-pin
NOSHOK, Inc.
•
1010 West Bagley Road, Berea, OH 44017
•
Ph: 440.243.0888
•
Fax 440.243.3472
•
www.noshok.com
1
0
3
5
CANOpen
Output signal
CANopen protocol in acc.with CiA DS-301
V.402,
Device profile DS-404 V. 1.2
Reproducibility
≤ ± 0.05 % of setting
Stability per year
≤ ± 0.2 % of setting under reference conditions
Electrical connection
Round connector M12 x 1 - 5-pin.
Auxiliary power
10 ... 30 VDC
)
W
7
.
0
<
n
o
it
a
r
a
p
e
s
c
i
n
a
v
l
a
g
h
ti
w
(
W
5
.
0
<
n
o
it
p
m
u
s
n
o
c
r
e
w
o
P
Communication services
LSS (CiA DSP 305, Version 1.1.1) Services
Configuration of device address and baud rate
Sync/Async, Node/Lifeguarding, Heartbeat
Filters
Individually programmable filters for specific
removal of resonance frequencies, for example
Adjustment
Zero point and measuring range ±10% by
making entries in object directory
Adjustment time
1.5 ms (baud rate ≥ 125K) within
10 % up to 90 % of setting.
Measuring frequency
Internal 1000 Hz (adjustable up to approx. 4 Hz)
Measuring element made from stainless steel