21

Range & Accuracy

Range

Min

Max

Accuracy
(% of reading ±

counts)

V Read (low)

0.000

20.000

0.015% ±2

VDC Read (high)

0.0

250.0

0.05% ±2

VAC Read (high)

0.0

250.0

0.5% ±2

V Source

0.000

20.000

0.015% ±2

mV Read

-10.00

75.00

0.015% ±2

mV Source

-10.00

75.00

0.015% ±2

mA Read

0.000

24.000

0.015% ± 2

mA Source

0.000

24.000

0.015% ± 2

CPM Source

2.0

1000.0

0.05%

Hz Source

1

1000

0.05%

KHz Source

1.0

10.0

0.25%

CPM Read

0.0

1000.0

0.05% ± 1

Hz Read

0.0

1000.0

0.05% ± 1

KHz Read

0.00

10.00

0.05% ± 1

Range

Min

Max

Accuracy

Ohms Read (low)

0.00

400.00

0.1 ohm

Ohms Read (high)

400.0

1500.0

0.5 ohm

1500.1

3200.0

1.0 ohm

Range

Min

Max

Excitation Accuracy
Current

Ohms Source (low)

5.00

400.00

0.1 to 0.5 mA

0.15 ohm

5.00

400.00

0.5 to 3 mA

0.1 ohm

Ohms Source (high)

400.0

1500.0

0.05 to 0.8 mA

0.5 ohm

1500.0

3200.0

0.05 to 0.4 mA

1.0 ohm

Thermocouple Read and Source (All errors included)
Range

Min

Max

Accuracy

J Thermocouple

-200.0

0.0

0.6°C

0.0

1200.0

0.4°C

K Thermocouple

-200.0

0.0

0.8°C

0.0

1370.0

0.5°C

T Thermocouple

-200.0

0.0

0.8°C

0.0

400.0

0.5°C

E Thermocouple

-200.0

0.0

0.5°C

0.0

950.0

0.4°C

R Thermocouple

-20

0.0

2.49°C

0

500

1.7°C

500

1750

1.3°C

S Thermocouple

-20

0

2.4°C

0

500

1.7°C

500

1750

1.4°C

B Thermocouple

600

800

2.1°C

800

1000

1.7°C

1000

1800