Maintenance / warranty – Martel Electronics PSC4010 User Manual
Page 32
![background image](/manuals/369796/32/background.png)
7. Maintenance / Warranty
7.1 Replacing Batteries
Replace batteries as soon as the battery indicator turns on to avoid false measurements. If
the batteries discharge too deeply the PSC4010 will automatically shut down to avoid battery
leakage.
Note: Use only AA size alkaline batteries or optional rechargeable battery pack.
7.2 Cleaning the Unit
Warning
To avoid personal injury or damage to the calibrator, use only the specified replacement parts
and do not allow water into the case.
Caution
To avoid damaging the plastic lens and case, do not use solvents or abrasive cleansers.
Clean the calibrator with a soft cloth dampened with water or water and mild soap.
7.3 Service Center Calibration or Repair
Only qualified service personnel should perform calibration, repairs, or servicing not covered
in this manual. If the calibrator fails, check the batteries first, and replace them if needed.
Verify that the calibrator is being operated as explained in this manual. If the calibrator is
faulty, send a description of the failure with the calibrator. Be sure to pack the calibrator
securely, using the original shipping container if it is available. To return the product to Martel
go to www.martelcalibrators.com and click on the Customer Service link. Download the RMA
form and follow the instructions. Calibration procedures and other related documents can
also be found on the website.
7.4 Replacement Parts & Accessories
CC572
Carrying Case
C232SJ
RS232 Cable with Miniature Plug
1919896
USB/RS232 Converter Cable with Miniature Plug
5353050
48" Stackable Testleads
1001-9V
Battery Adapter/Charger
7.5 Warranty
Martel Electronics Corporation warrants all products against material defects and
workmanship for a period of twelve (12) months after the date of shipment. Problems or
defects that arise from misuse or abuse of the instrument are not covered. If any product is to
be returned, a “Return Material Authorization” form can be obtained from our website
www.martelcorp.com under customer service. You can also call 1-800-821-0023 to have a
form faxed. Martel will not be responsible for damage as a result of poor return packaging.
Out of warranty repairs and recalibration will be subject to specific charges. Under no
circumstances will Martel Electronics be liable for any device or circumstance beyond the
value of the product.
30