― 30 ―

Operating System

Dual Integration

Display

Liquid crystal display with a maximum
count of 4000

Low Battery Warning

"BATT" symbol is displayed on the digital
display.

Overrange Indication

"OL" is displayed where input exceeds
the upper limit of a range

Response Time

Approx. 2 seconds

Sleep function

Automatically powered down in about 10
minutes after the last switch operation

Data Hold

Available in all ranges provided the peak
measurement mode is deactivated.

Operating Environmental indoor use
conditions

altitude up to 2000m

Storage Temperature

20

60

, relative humidity up to 85%

and Humidity

without condensation

Operating Temperature

0

40

, relative humidity up to 85%

and Humidity

without condensation

Conductor Size

Approx. 54.5

diameter max.

Overload Protection

2400A AC for 10sec
1200V AC/DC for 10sec
600V AC for 10sec

Withstand Voltage

5320V AC for 5 seconds between electrical
circuit and housing cases or metal parts
of jaws

Insulation Resistance

10M

Ω

or greater at 1000V between

electrical circuit and housing cases or
metal parts of jaws

Safety Standard

IEC 61010-1: Measurement CAT.

600V/CAT.

1000V, pollution degree 2.

Dimensions

247

L

×

105

W

×

49

D

mm

Weight

Approx. 470g(battery included)

Power Source

Two R6P(DC1.5V) batteries or equivalent

Current Consumption

Approx. 5mA max. (Approx. 20

μ

A in the

sleep mode)

Accessories

Test leads M-7107
Two R6P batteries
Instruction manual
Recorder Output Plug M-8201
Carrying case M-9094

Optional Accessories

Multi-Tran M-8008
Output Probe M-7014, etc.

.