DANGER
●
Never make measurement on the circuit above 750VAC or 1000VDC.
●
Do not attempt to make measurement in the presence of flammable
gasses, fumes, vapor or dust. Otherwise, the use of the instrument
may cause sparking, which can lead to an explosion.
●
Transformer jaw tips are designed not to short the circuit under
test. If equipment under test has exposed conductive parts,
however, extra precaution should be taken to minimize the
possibility of shorting.
●
Never attempt to use the instrument if its surface or your hand is wet.
●
Do not exceed the maximum allowable input of any measurement
range.
●
Never open the battery compartment cover and the instrument case
when making measurement.
●
Verify proper operation on a known source before use or taking
action as a result of the indication of the instrument.
WARNING
●
Never attempt to make any measurement if any abnormal conditions
are noted, such as broken case, cracked test leads and exposed
metal parts.
●
Do not turn the function selector switch with test leads connected to
the instrument.
●
Do not install substitute parts or make any modification to the
instrument. Return the instrument to your distributor for repair or re-
calibration.
●
Do not try to replace the batteries if the surface of the instrument is wet.
●
Always switch off the instrument and make sure to disconnect test leads
before opening the battery compartment cover for battery replacement.
CAUTION
●
Always make sure to check the function selector switch is set to an
appropriate position before starting measurement.
●
Always make sure to insert the plug of each lead fully into the
appropriate terminal on the instrument.
●
Be sure to set the function selector switch to the "OFF" position
after use. When the instrument will not be in use for a long period,
place it in storage after removing the batteries.
●
Do not expose the instrument to the direct sun, high temperature or
dew fall.
●
Use a cloth dipped in water or neutral detergent for cleaning the
instrument. Do not use abrasives or solvents.