beautypg.com

Technical data, 2 technical data – KROHNE LS 6500 EN User Manual

Page 27

background image

TECHNICAL DATA

7

27

LS 6500

www.krohne.com

03/2013 - 4000649103 - MA LS 6500 R03 en

7.2 Technical data

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Measuring principle

Electromagnetic wave, 100..180 MHz

Application range

Level detection, dry-run protection and media separation of liquids and

solids.

Design

Construction

The measurement system consists of a measuring sensor and the electronic

unit which is available in a compact version. The switching point is signalled

by a blue LED indication through the housing cover.

Options

Sliding connection / extension for high-temperature applications

Teach-In function for applications where the medium is hard to detect.

Accessories

Comprehensive range of adapters and process connections for hygienic

installation. Please refer to the specific data sheet "Accessories".

Measuring accuracy

Resolution

±

1 mm / ±0.04"

Hysteresis

±

1 mm / ±0.04"

Reference conditions acc. to EN 60770

Reference conditions acc. to EN 60770

Reference conditions acc. to EN 60770

Reference conditions acc. to EN 60770

Temperature

+20°C ±5°C / +70°F ±10°F

Pressure

1013 mbar abs. ±20 mbar / 14.69 psig ±0.29 psig

Relative air humidity

60% ±15%

Operating conditions

Temperature

Temperature

Temperature

Temperature

Ambient temperature (T

amb

)

-40…+85°C / -40…+185°F

Process temperature

-40…+85°C / -40…+185°F (short version and DN38 connection)

< 1 hour, T

amb

< 60°C / 140°F: -40…+140°C / -40…+284°F

-40 …+200°C / -40...+392°F (with sliding connection)

Pressure

Pressure

Pressure

Pressure

Ambient pressure

Atmosphere

Process pressure

Standard and DN38 connection: max. 40 bar / 580 psi

Sliding connection: max. 16 bar / 232 psi

Other conditions

Other conditions

Other conditions

Other conditions

Protection category

(acc. to EN 60529)

IP67 equivalent to NEMA 4X

Installation conditions

Installation

In any position. For detailed information refer to chapter "Installation".

Dimensions and weights

For detailed information refer to chapter "Dimensions and weights".

.book Page 27 Tuesday, March 12, 2013 11:33 AM