DWM 2000 IP68

The version IP68 is supplied as a sealed unit, with all calibration
carried out before delivery. The customer has to be aware in
particular that the cable packing gland must not be opened as it
is specially sealed according to regulations.

Ensure to install the unit onto the flowpipe before connecting the
cable, as the cable needs to be free during the rotation of the
unit. The unit must be installed with the flow arrow marked on
the top of the housing aligned with the flow in the pipe.

For the wiring of the versions IP68, see the two diagrams below,
showing the two options of a common or separate power sup-
plies. The numbering corresponds to the following wire colours:
11 - Brown; 12 - Red; 5 - Orange; 6 - Yellow

For all electrical information refer to DWM2000 Technical Data
specifications on page 11.

The DWM 2000 IP68 can also be ordered with extended probe,
as detailed below in the DWM 2000 L.

Wiring:
Common Power Supply

Separate Power Supply

11 -

12 +

5 +

6 -

VDC

11 -

12 +

5 +

6 -

VDC

VDC

11 - brown; 12 - red; 5 - orange; 6 - yellow

DWM 2000 L

Characteristics

Same characteristics as DWM2000 but adapted for the
following special conditions:

n

Velocity measurement in open channel. Combined with ultra-

sonic level measurement gives flow volume measurement.

n

Flow control in pipes or open channels.

n

Spool piece mounting, T-mounting.

n

Option: Hot-tap mounting, equipped with isolation valve.

n

Option: adjustable high pressure screw connection with securi-
ty chain for mounting and dismounting.

n

Can be used instead of insertion turbines, flow controllers.

n

Possibility to measure velocity at different points in open chan-
nels, rivers etc.

n

Probe lengths up to 3m possible.

n

Easy to transport in order to carry out field tests.

n

Protection class IP55.

n

Special option IP68 with submerged converter.

Max Product Temperature: 150°C (IP55), 60°C (IP68)
Max Operating Pressure: 25 bar
Ambient Temperature Range: -25°C to + 60°C

M20 x 1.5