beautypg.com

Technical data, 4 guidelines for maximum operating pressure – KROHNE OPTIMASS 7000 EN User Manual

Page 40

background image

6

TECHNICAL DATA

40

OPTIMASS 7000

www.krohne.com

04/2013 - 4001016302 - MA OPTIMASS 7000 R02 en

6.4 Guidelines for maximum operating pressure

Notes

• Ensure that the meter is used within its operating limits
• All hygienic process connections have a maximum operating rating of 10 barg at 150°C /

145 psig at 302°F

Pressure / temperature de-rating for Titanium Gr 9 meters

Pressure / temperature de-rating for Titanium Gr 9 meters

Pressure / temperature de-rating for Titanium Gr 9 meters

Pressure / temperature de-rating for Titanium Gr 9 meters
(all meter sizes, with flanged connections as per EN 1092-1 and JIS B 2220)

(all meter sizes, with flanged connections as per EN 1092-1 and JIS B 2220)

(all meter sizes, with flanged connections as per EN 1092-1 and JIS B 2220)

(all meter sizes, with flanged connections as per EN 1092-1 and JIS B 2220)

X temperature [°C]
Y pressure [barg]

1 Standard tube and outer cylinder 316L (100 barg PED option) with PN100 flanges (sizes DN06...25)
2 Standard tube and outer cylinder 316L (100 barg PED option) with PN100 flanges (sizes DN40...80)
3 DIN 2637 PN63 flanges
4 Outer cylinder (63 barg PED / CRN option)
5 JIS 20K flanges
6 DIN 2635 PN40 flanges
7 JIS 10K flanges
8 Hygienic connections