3.4.9 Heating and insulation

Heating

Heating

Heating

Heating

The meter can be heated by electrical tape (or similar) as shown. ONLY heat the meter in the
area marked A.

Insulation

Insulation

Insulation

Insulation

The meter can also be insulated to a maximum depth as shown (B). Do not insulate above this
depth as this will cause the electronics to overheat.

Heated area

Electrical heating and insulation

1 Area that can be heated (A). Refer to the table for the maximum sizes.
2 Maximum depth of insulation (B). DO NOT insulate above this depth.

Dimension of A [mm]

10

15

25

40

50

80

Titanium

50

65

120

150

200

410

Stainless Steel / Hastelloy® / Tantalum

-

65

75

150

125

225

Dimension of A [inches]

10

15

25

40

50

80

Titanium

1.97

2.56

4.7

5.9

7.9

16.1

Stainless Steel / Hastelloy® / Tantalum

-

2.56

2.9

5.9

4.9

8.8

MA_OPTIMASS_7000_en_042513_4001016302_R02.book Page 23 Tuesday, July 2, 2013 5:23 PM