Factory fitted heating jacket
Factory fitted heating jacket
Factory fitted heating jacket
Factory fitted heating jacket
If the meter has been ordered with a heating jacket, it will be supplied with NPT, Ermeto or
flange connections.
Connecting / using the heating jacket
• Use reinforced flexible hoses to connect the heating jacket to the heat source.
• The heating jacket material is 316L but the heating medium is also in contact with the outer
cylinder, which might be a lower grade Stainless Steel.
• Suitable heating mediums are steam or hot oil. Avoid the use of heating mediums that can
cause crevice corrosion in Stainless Steel.
• Where liquid is being used, set up the pipe configuration so that air can be vented from the
system.
• Where steam is being used, set up the pipe configuration so that condensation can be drained
off.
• Heat the jacket to working temperature before flowing the process fluid through the meter.
Heating times
CAUTION!
The maximum heating jacket pressure and temperature is 10 barg at 150°C / 145 psig at 302°F
for Titanium measuring tubes and 10 barg at 100°C / 145 psig at 212°C for Stainless Steel,
Hasteloy and Tantalum measuring tubes.
Temperature [°C / °F] 1
Time [minutes] for Titanium measuring tube
10
15
25
40
50
80
40 / 104
30
90
60 / 140
80
160
80 / 176
120
330
100 / 212
190
495
120 / 248
270
735
140 / 284
480
1320
1 Measured at the centre of the measuring tube.