3

INSTALLATION

24

OPTIMASS 7000

www.krohne.com

04/2013 - 4001016302 - MA OPTIMASS 7000 R02 en

Factory fitted heating jacket

Factory fitted heating jacket

Factory fitted heating jacket

Factory fitted heating jacket

If the meter has been ordered with a heating jacket, it will be supplied with NPT, Ermeto or
flange connections.

Connecting / using the heating jacket

• Use reinforced flexible hoses to connect the heating jacket to the heat source.
• The heating jacket material is 316L but the heating medium is also in contact with the outer

cylinder, which might be a lower grade Stainless Steel.

• Suitable heating mediums are steam or hot oil. Avoid the use of heating mediums that can

cause crevice corrosion in Stainless Steel.

• Where liquid is being used, set up the pipe configuration so that air can be vented from the

system.

• Where steam is being used, set up the pipe configuration so that condensation can be drained

off.

• Heat the jacket to working temperature before flowing the process fluid through the meter.

Heating times

CAUTION!
The maximum heating jacket pressure and temperature is 10 barg at 150°C / 145 psig at 302°F
for Titanium measuring tubes and 10 barg at 100°C / 145 psig at 212°C for Stainless Steel,
Hasteloy and Tantalum measuring tubes.

Temperature [°C / °F] 1

Time [minutes] for Titanium measuring tube

10

15

25

40

50

80

40 / 104

30

90

60 / 140

80

160

80 / 176

120

330

100 / 212

190

495

120 / 248

270

735

140 / 284

480

1320

1 Measured at the centre of the measuring tube.

MA_OPTIMASS_7000_en_042513_4001016302_R02.book Page 24 Tuesday, July 2, 2013 5:23 PM