beautypg.com

Technical data, Inputs and outputs – KROHNE OPTIFLUX 7300 EN User Manual

Page 29

background image

TECHNICAL DATA

6

29

OPTIFLUX 7300

www.krohne.com

01/2011 - 4001163301 - MA OPTIFLUX 7300 R01 en

Inputs and outputs

General

All outputs are electrically isolated from each other and from all other

circuits.

All operating data and output values van be adjusted.

Description of the used

abbreviations

U

ext

= external voltage

R

L

= load + resistance

U

o

= terminal voltage

l

nom

= nominal current

Safety limit values (Ex i):

Safety limit values (Ex i):

Safety limit values (Ex i):

Safety limit values (Ex i):

U

i

= max. input voltage

l

l

= max. input current

P

l

= max. input power rating

C

l

= max. input capacity

L

l

= max. input inductivity

Current output

Current output

Current output

Current output

Output data

Volume flow, mass flow, diagnostics value, flow velocity, coil temperature.

Settings

Without HART

Without HART

Without HART

Without HART

®

Q = 0%: 0...20 mA

Q = 100%: 10...21.5 mA

Error identifications: 10...21.5 mA

With HART

With HART

With HART

With HART

®

Q = 0%: 4...20 mA

Q = 100%: 10...21.5 mA

Error identifications: 3.5...22 mA

Operating Data

Basic I/Os

Basic I/Os

Basic I/Os

Basic I/Os

Modular I/Os

Modular I/Os

Modular I/Os

Modular I/Os

Ex i

Ex i

Ex i

Ex i

Active

U

int, nom

= 24 VDC

I ≤ 22 mA

R

L

≤ 1 kΩ

U

int, nom

= 20 VDC

I ≤ 22 mA

R

L

≤ 450 Ω

U

0

= 21 V

I

0

= 90 mA

P

0

= 0.5 W

C

0

= 90 nF /

L

0

= 2 mH

C

0

= 110 nF /

L

0

= 0.5 mH

Passive

U

ext

≤ 32 VDC

I ≤ 22 mA

U

0

≥ 1.8 V

R

L

≤ (U

ext

- U

0

) / I

max

U

ext

≤ 32 VDC

I ≤ 22 mA

U

0

≥ 4 V

R

L

≤ (U

ext

- U

0

) / I

max

U

i

= 30 V

I

i

= 100 mA

P

i

= 1 W

C

i

= 10 nF

L

i

~ 0 mH