beautypg.com

Technical data – KROHNE OPTIFLUX 7300 EN User Manual

Page 26

background image

6

TECHNICAL DATA

26

OPTIFLUX 7300

www.krohne.com

01/2011 - 4001163301 - MA OPTIFLUX 7300 R01 en

Remote control

PACTware

®

(incl. Device Type Manager (DTM))

HART

®

Hand Held Communicator from Emerson Process

AMS

®

from Emerson Process

PDM

®

from Siemens

All DTMs and drivers are available free of charge from the

manufacturer's website.

Display functions

Display functions

Display functions

Display functions

Operating menu

Setting the parameters using 2 measured value pages, 1 status page,

1 graphics page (measured values and graphics are freely

adjustable).

Language display texts

(as language package)

Standard: English, French, German, Dutch, Portuguese, Swedish,

Spanish, Italian

Eastern Europe: English, Slovenian, Czech, Hungarian

Northern Europe: English, Danish, Polish

China: English, Chinese

Russia: English, Russian

Units

Metric, British and US units selectable as required from lists for

volume / mass flow and counting, flow velocity, temperature.

Measuring accuracy

Reference conditions

Flow conditions: similar to EN 29104

Medium: water

Temperature: 20°C / 68°F

In-/outlet section: 10 DN / 5 DN

Flow velocity: > 1 m/s / > 3 ft/s

Operating pressure: 1 bar / 14.5 psig

Valve closing time variation: < 1 ms

Wet calibrated on EN 17025 accredited calibration rig by direct

volume comparison.

Maximum measuring error

±0.5% of measured value ±5 mm/s

Related to volume flow.

These values are related to the pulse / frequency output.

The additional typical measuring deviation for the current output

is ±10 μA.

Repeatability

±

0.1% of MV, minimum 1 mm/s

Long term stability

±

0.1% of MV

Special calibration

On request