6
TECHNICAL DATA
26
OPTIFLUX 7300
www.krohne.com
01/2011 - 4001163301 - MA OPTIFLUX 7300 R01 en
Remote control
PACTware
®
(incl. Device Type Manager (DTM))
HART
®
Hand Held Communicator from Emerson Process
AMS
®
from Emerson Process
PDM
®
from Siemens
All DTMs and drivers are available free of charge from the
manufacturer's website.
Display functions
Display functions
Display functions
Display functions
Operating menu
Setting the parameters using 2 measured value pages, 1 status page,
1 graphics page (measured values and graphics are freely
adjustable).
Language display texts
(as language package)
Standard: English, French, German, Dutch, Portuguese, Swedish,
Spanish, Italian
Eastern Europe: English, Slovenian, Czech, Hungarian
Northern Europe: English, Danish, Polish
China: English, Chinese
Russia: English, Russian
Units
Metric, British and US units selectable as required from lists for
volume / mass flow and counting, flow velocity, temperature.
Measuring accuracy
Reference conditions
Flow conditions: similar to EN 29104
Medium: water
Temperature: 20°C / 68°F
In-/outlet section: 10 DN / 5 DN
Flow velocity: > 1 m/s / > 3 ft/s
Operating pressure: 1 bar / 14.5 psig
Valve closing time variation: < 1 ms
Wet calibrated on EN 17025 accredited calibration rig by direct
volume comparison.
Maximum measuring error
±0.5% of measured value ±5 mm/s
Related to volume flow.
These values are related to the pulse / frequency output.
The additional typical measuring deviation for the current output
is ±10 μA.
Repeatability
±
0.1% of MV, minimum 1 mm/s
Long term stability
±
0.1% of MV
Special calibration
On request