beautypg.com

Installation, 2 torques and pressures flanged versions – KROHNE OPTIFLUX 7300 EN User Manual

Page 18

background image

3

INSTALLATION

18

OPTIFLUX 7300

www.krohne.com

01/2011 - 4001163301 - MA OPTIFLUX 7300 R01 en

3.5.2 Torques and pressures flanged versions

Tighten the bolts in fixed order, see picture:

• Step 1: by hand
• Step 2: approx. 25% of max. torque
• Step 3: approx. 50% of max. torque
• Step 4: approx. 80% of max. torque
• Step 5: 100% of max. torque given in table

EN 1092-1

WARNING!
Use stainless steel A2 / 6.9 class bolts.

INFORMATION!
Diameters DN80 and DN100 have 8 holes per flange, please continue in the same way to tighten
the other bolts.

CAUTION!
With the instrument, 4 PTFE sealing rings are included (2 to be used with installation,
2 as spare).
No other gaskets are required.

Nominal size

DN [mm]

Pressure

rating

Bolts

Max. torque

[Nm]

25

PN 40

4 × M 12

73.5

40

PN 40

4 × M 16

178

50

PN 40

4 × M 16

178

80

PN 40

8 × M 16

178

100

PN 16

8 × M 16

178