beautypg.com

Technical data – KROHNE OPTIFLUX 5000 Sandwich EN User Manual

Page 32

background image

6

TECHNICAL DATA

32

OPTIFLUX 5000

www.krohne.com

10/2011 - 4000686202 - MA OPTIFLUX 5000 SW R02 en

Nominal

size

Dimensions [mm]

Approx.

weight [kg]

DN

L

H

W

D

Ød1

Ød4

2.5

65

1

123

44

-

-

1.6

4

65

1

123

44

-

-

1.6

6

65

1

123

44

-

-

1.6

10

65

1

123

44

-

-

1.6

15

65

1

123

44

-

-

1.6

25

58

2

116

68

20

26

46

1.6

40

83

2

131

83

30

39

62

2.4

50

103

2

149

101

40

51

74

2.9

80

153

2

181

133

60

80

106

6.4

100

203

2

206

158

80

101

133

8.8

1 Total fitting length of flowmeter with integrated rings: dimension L + 2 x gasket thickness.
2 Total fitting length of flowmeter without rings: dimension L only.

Nominal

size

Dimensions [inches]

Approx.

weight [lb]

ASME

L

H

W

D

Ød1

Ød4

1/10"

2.56

1

4.84

1.73

-

-

3.53

1/8"

2.56

1

4.84

1.73

-

-

3.53

¼

"

2.56

1

4.84

1.73

-

-

3.53

3/8"

2.56

1

4.84

1.73

-

-

3.53

½

"

2.56

1

4.84

1.73

-

-

3.53

1"

2.28

2

4.57

2.68

0.79

1.02

1.81

3.53

1½"

3.27

2

5.16

3.27

1.18

1.54

2.44

5.29

2"

4.06

2

5.87

3.98

1.57

2.01

2.91

6.39

3"

6.02

2

7.13

5.24

2.36

3.15

4.17

14.11

4"

7.99

2

8.11

6.22

3.15

3.98

5.24

19.40

1 Total fitting length of flowmeter with integrated rings: dimension L + 2 x gasket thickness.
2 Total fitting length of flowmeter without rings: dimension L only.

CAUTION!

Pressures at 20°C / 68°F.

For higher temperatures, the pressure and temperature ratings are as per ASME B16.5.

.book Page 32 Monday, October 3, 2011 1:46 PM